Files
fresh-home/esphome/archive/new-furnace-room-multisensor.yaml
T

230 lines
5.7 KiB
YAML

# 3v3 en svp sun 34 35 32 33 25 26 27 14 12 gnd 13 sd2 sd3 gnd 5v
substitutions:
devicename: furnace-room-multisensor
entity_name: furnace_room_multisensor
friendly_name: Furnace Room MultiSensor
comment: Clever MultiSensor
platform: ESP32
board: esp32dev
static_ip: !secret furnace-room-multisensor-ip
one_wire_pin: GPIO16
sda_pin: GPIO21
scl_pin: GPIO22
door_pin: GPIO27
trigger_pin: GPIO33
echo_pin: GPIO35
#mdc_pin: GPIO23
#mdio_pin: GPIO18
#clk_mode: GPIO17_OUT
#power_pin: GPIO5
packages:
#wifi: !include common/wifi_no_power_save.yaml
ethernet: !include common/ethernet.yaml
device_base: !include common/device_base.yaml
ble_proxy: !include common/ble_proxy.yaml
esphome:
name: ${devicename}
friendly_name: ${friendly_name}
esp32:
board: ${board}
framework:
type: esp-idf
# Enable logging
logger:
api: # Using settings from common/device_base.yaml
ota: # Using settings from common/device_base.yaml
wifi: # Using settings from common/wifi*.yaml
use_address: "192.168.1.230"
captive_portal:
esp32_ble_tracker:
globals:
- id: screen_power
type: bool
restore_value: yes
initial_value: 'true'
font:
- file: 'CascadiaMonoPL.ttf'
id: font1
size: 17
one_wire:
- platform: gpio
pin: ${one_wire_pin}
i2c:
# sda: GPIO13 #D1
# scl: GPIO15 #D2
sda: ${sda_pin}
scl: ${scl_pin}
frequency: 800kHz
display:
- platform: ssd1306_i2c
id: oled
model: "SSD1306 128x64"
#reset_pin: GPIO14 #D0
address: 0x3C
lambda: |-
it.print(0, 0, id(font1), "Delt:");
it.printf(128, 0, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_delta).state);
it.print(0, 16, id(font1), "HVAC:");
it.printf(128, 16, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac).state);
it.print(0, 32, id(font1), "Retn:");
it.printf(128, 32, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_return).state);
it.print(0, 48, id(font1), "Ambt:");
it.printf(128, 48, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(ambient).state);
sensor:
- platform: dallas_temp
address: 0xB33C01B607798528
name: "Return Temperature"
id: hvac_return
update_interval: 10s
filters:
- lambda: return x * (9.0/5.0) + 32.0;
unit_of_measurement: "°F"
state_class: measurement
- platform: dallas_temp
address: 0x0F3C01B6070C1328
name: "HVAC Temperature"
id: hvac
update_interval: 10s
filters:
- lambda: return x * (9.0/5.0) + 32.0;
unit_of_measurement: "°F"
state_class: measurement
- platform: dallas_temp
address: 0xFA3C01B607005B28
name: "Furnace Room Temperature"
id: ambient
update_interval: 10s
filters:
- lambda: return x * (9.0/5.0) + 32.0;
unit_of_measurement: "°F"
state_class: measurement
- platform: template
name: "HVAC Delta"
id: hvac_delta
lambda: |-
return (id(hvac).state - id(hvac_return).state);
update_interval: 10s
unit_of_measurement: "°F"
state_class: measurement
filters:
- or:
- throttle: 60s
- delta: 1.0
- platform: ultrasonic
trigger_pin: ${trigger_pin}
echo_pin: ${echo_pin}
id: ultrasonic_source
#update_interval: 5s
internal: True
filters:
- sliding_window_moving_average:
window_size: 5
send_every: 5
send_first_at: 1
on_value:
then:
- sensor.template.publish:
id: distance_from_bottom
state: !lambda 'return id(ultrasonic_source).state;'
- sensor.template.publish:
id: distance_from_top
state: !lambda 'return id(ultrasonic_source).state;'
- platform: template
unit_of_measurement: "cm"
state_class: measurement
id: distance_from_bottom
name: "Salt Level in CM"
#update_interval: 5s
filters:
- lambda: 'return (0.94 - (id(ultrasonic_source).state)) * 100;'
on_value:
then:
- sensor.template.publish:
id: level_in_bags
state: !lambda 'return id(distance_from_bottom).state;'
- platform: template
unit_of_measurement: "cm"
state_class: measurement
id: distance_from_top
name: "Salt Level From Top in CM"
#update_interval: 5s
filters:
- lambda: 'return (id(ultrasonic_source).state) * 100;'
- platform: template
unit_of_measurement: "bags"
state_class: measurement
id: level_in_bags
name: "Salt Level in Bags"
#update_interval: 5s
filters:
- lambda: 'return (id(distance_from_bottom).state) / 17.5;'
binary_sensor:
- platform: gpio
name: "Furnace Room Door"
device_class: door
pin:
number: ${door_pin}
#mode: INPUT_PULLUP
- platform: homeassistant
internal: true
id: light_state
entity_id: light.furnace_room
on_state:
then:
- if:
condition:
lambda: 'return id(light_state).state;'
then:
- logger.log: "The light is on"
else:
- logger.log: "The is off. Turning off display"
- switch.turn_off: display_switch
switch:
- platform: template
id: display_switch
name: "HVAC Display Switch"
lambda: |-
if (id(screen_power)) {
id(oled).turn_on();
} else {
id(oled).turn_off();
}
return id(screen_power);
turn_on_action:
- lambda: |-
id(screen_power) = true;
// id(oled).turn_on();
turn_off_action:
- lambda: |-
id(screen_power) = false;
// id(oled).turn_off();