YAML

# 3v3 en svp sun 34 35 32 33 25 26 27 14 12 gnd 13 sd2 sd3 gnd 5v
substitutions:
devicename: hvac-multisensor-425f4f
entity_name: hvac_multisensor
friendly_name: HVAC MultiSensor
comment: Clever MultiSensor
platform: ESP32
board: wemos_d1_mini32
static_ip: !secret hvac-multisensor-ip
sda_pin: GPIO21
scl_pin: GPIO22
door_pin: GPIO19
one_wire_pin: GPIO14
trigger_pin: GPIO04
echo_pin: GPIO12
#mdc_pin: GPIO23
#mdio_pin: GPIO18
#clk_mode: GPIO17_OUT
#power_pin: GPIO5
packages:
#wifi: !include common/wifi_no_power_save.yaml
ethernet: !include common/ethernet.yaml
device_base: !include common/device_base.yaml
ble_proxy: !include common/ble_proxy.yaml
esphome:
name: ${devicename}
friendly_name: ${friendly_name}
name_add_mac_suffix: false
esp32:
board: ${board}
framework:
type: esp-idf
web_server:
port: 80
version: 3
include_internal: true
# Enable logging
logger:
api: # Using settings from common/device_base.yaml
ota: # Using settings from common/device_base.yaml
esp32_ble_tracker:
# globals:
# - id: screen_power
# type: bool
# restore_value: yes
# initial_value: 'true'
# font:
# - file: 'CascadiaMonoPL.ttf'
# id: font1
# size: 17
# one_wire:
# - platform: gpio
# pin: ${one_wire_pin}
# i2c:
# sda: ${sda_pin}
# scl: ${scl_pin}
# frequency: 800kHz
# display:
# - platform: ssd1306_i2c
# id: oled
# model: "SSD1306 128x64"
# #reset_pin: GPIO14 #D0
# address: 0x3C
# lambda: |-
# it.print(0, 0, id(font1), "Delta:");
# it.printf(128, 0, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_delta).state);
# it.print(0, 16, id(font1), "Supply:");
# it.printf(128, 16, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_supply).state);
# it.print(0, 32, id(font1), "Return:");
# it.printf(128, 32, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_return).state);
# it.print(0, 48, id(font1), "Ambient:");
# it.printf(128, 48, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(ambient).state);
# sensor:
# - platform: dallas_temp
# address: 0xB33C01B607798528
# name: "Return Temperature"
# id: hvac_return
# update_interval: 10s
# filters:
# - lambda: return x * (9.0/5.0) + 32.0;
# unit_of_measurement: "°F"
# state_class: measurement
# - platform: dallas_temp
# address: 0x0F3C01B6070C1328
# name: "Supply Temperature"
# id: hvac_supply
# update_interval: 10s
# filters:
# - lambda: return x * (9.0/5.0) + 32.0;
# unit_of_measurement: "°F"
# state_class: measurement
# - platform: dallas_temp
# address: 0xFA3C01B607005B28
# name: "Ambient Temperature"
# id: ambient
# update_interval: 10s
# filters:
# - lambda: return x * (9.0/5.0) + 32.0;
# unit_of_measurement: "°F"
# state_class: measurement
# - platform: template
# name: "Delta Temperature"
# id: hvac_delta
# lambda: |-
# return (id(hvac_supply).state - id(hvac_return).state);
# update_interval: 10s
# unit_of_measurement: "°F"
# state_class: measurement
# filters:
# - or:
# - throttle: 60s
# - delta: 1.0
# - platform: ultrasonic
# trigger_pin: ${trigger_pin}
# echo_pin: ${echo_pin}
# id: ultrasonic_source
# #update_interval: 5s
# internal: True
# filters:
# - sliding_window_moving_average:
# window_size: 5
# send_every: 5
# send_first_at: 1
# on_value:
# then:
# - sensor.template.publish:
# id: distance_from_bottom
# state: !lambda 'return id(ultrasonic_source).state;'
# - sensor.template.publish:
# id: distance_from_top
# state: !lambda 'return id(ultrasonic_source).state;'
# - platform: template
# unit_of_measurement: "cm"
# state_class: measurement
# id: distance_from_bottom
# name: "Salt Level in CM"
# #update_interval: 5s
# filters:
# - lambda: 'return (0.94 - (id(ultrasonic_source).state)) * 100;'
# on_value:
# then:
# - sensor.template.publish:
# id: level_in_bags
# state: !lambda 'return id(distance_from_bottom).state;'
# - platform: template
# unit_of_measurement: "cm"
# state_class: measurement
# id: distance_from_top
# name: "Salt Level From Top in CM"
# #update_interval: 5s
# filters:
# - lambda: 'return (id(ultrasonic_source).state) * 100;'
# - platform: template
# unit_of_measurement: "bags"
# state_class: measurement
# id: level_in_bags
# name: "Salt Level in Bags"
# #update_interval: 5s
# filters:
# - lambda: 'return (id(distance_from_bottom).state) / 17.5;'
# binary_sensor:
# - platform: gpio
# name: "Door"
# device_class: door
# pin:
# number: ${door_pin}
# mode: INPUT_PULLUP
# switch:
# - platform: template
# id: display_switch
# name: "Display"
# lambda: |-
# if (id(screen_power)) {
# id(oled).turn_on();
# } else {
# id(oled).turn_off();
# }
# return id(screen_power);
# turn_on_action:
# - lambda: |-
# id(screen_power) = true;
# // id(oled).turn_on();
# turn_off_action:
# - lambda: |-
# id(screen_power) = false;
# // id(oled).turn_off();