# Example configuration entry sensor: - platform: bme680 temperature: name: "BME680 Temperature" oversampling: 16x pressure: name: "BME680 Pressure" humidity: id: "humidity" name: "BME680 Humidity" gas_resistance: id: "gas_resistance" name: "BME680 Gas Resistance" address: 0x77 update_interval: 60s - platform: template name: "BME680 Indoor Air Quality" id: iaq icon: "mdi:gauge" # calculation: comp_gas = log(R_gas[ohm]) + 0.04 log(Ohm)/%rh * hum[%rh] lambda: |- return log(id(gas_resistance).state) + 0.04 * id(humidity).state; state_class: "measurement" text_sensor: - platform: template name: "BME680 IAQ Classification" icon: "mdi:checkbox-marked-circle-outline" lambda: |- if (int(id(iaq).state) <= 50) { return {"Excellent"}; } else if (int(id(iaq).state) <= 100) { return {"Good"}; } else if (int(id(iaq).state) <= 150) { return {"Lightly polluted"}; } else if (int(id(iaq).state) <= 200) { return {"Moderately polluted"}; } else if (int(id(iaq).state) <= 250) { return {"Heavily polluted"}; } else if (int(id(iaq).state) <= 350) { return {"Severely polluted"}; } else if (int(id(iaq).state) <= 500) { return {"Extremely polluted"}; } else { return {"unknown"}; }