# CircuitSetup 6 Channel Energy Meter 6th Add-on board config # Assumes jumpers are both in the 6th position sensor: #IC1 AddOn 6 ############ - platform: atm90e32 release_device: true cs_pin: 15 id: ${addon6_id1} phase_a: current: name: ${ct37_name} Amps id: ct37Amps power: name: ${ct37_name} Watts id: ct37Watts gain_voltage: ${voltage_cal1} gain_ct: ${current_cal_ct37} phase_b: current: name: ${ct38_name} Amps id: ct38Amps power: name: ${ct38_name} Watts id: ct38Watts gain_voltage: ${voltage_cal1} gain_ct: ${current_cal_ct38} phase_c: current: name: ${ct39_name} Amps id: ct39Amps power: name: ${ct39_name} Watts id: ct39Watts gain_voltage: ${voltage_cal1} gain_ct: ${current_cal_ct39} line_frequency: ${electric_freq} gain_pga: 1X update_interval: ${update_time} enable_offset_calibration: ${offset_calibration} enable_gain_calibration: ${gain_calibration} #IC2 AddOn 6 ############ - platform: atm90e32 release_device: true cs_pin: 26 id: ${addon6_id2} phase_a: current: name: ${ct40_name} Amps id: ct40Amps power: name: ${ct40_name} Watts id: ct40Watts gain_voltage: ${voltage_cal2} gain_ct: ${current_cal_ct40} phase_b: current: name: ${ct41_name} Amps id: ct41Amps power: name: ${ct41_name} Watts id: ct41Watts gain_voltage: ${voltage_cal2} gain_ct: ${current_cal_ct41} phase_c: current: name: ${ct42_name} Amps id: ct42Amps power: name: ${ct42_name} Watts id: ct42Watts gain_voltage: ${voltage_cal2} gain_ct: ${current_cal_ct42} line_frequency: ${electric_freq} gain_pga: 1X update_interval: ${update_time} enable_offset_calibration: ${offset_calibration} enable_gain_calibration: ${gain_calibration} #Total Amps AddOn6 - platform: template name: ${friendly_name} Total Amps Add-on6 id: totalAmpsAddOn6 lambda: return id(ct37Amps).state + id(ct38Amps).state + id(ct39Amps).state + id(ct40Amps).state + id(ct41Amps).state + id(ct42Amps).state ; accuracy_decimals: 2 unit_of_measurement: A device_class: current update_interval: ${update_time} #Total Watts AddOn6 - platform: template name: ${friendly_name} Total Watts Add-on6 id: totalWattsAddOn6 lambda: return id(ct37Watts).state + id(ct38Watts).state + id(ct39Watts).state + id(ct40Watts).state + id(ct41Watts).state + id(ct42Watts).state ; accuracy_decimals: 2 unit_of_measurement: W device_class: power update_interval: ${update_time}