binary_sensor: - platform: generic_hygrostat name: Master Bathroom Hygrostat sensor: sensor.bathroom_multisensor_relative_humidity # Source humidity sensor #attribute: humidity # Optional use sensor attribute instead of state. delta_trigger: 3 # Optional humidity swing to detect. Default = 3 target_offset: 10 # Optional dehumidification target offset. Default = 3 min_on_time: 300 # Optional min on time in seconds. Default = 0 seconds max_on_time: 1800 # Optional safety max on time in seconds. Default = 7200 seconds sample_interval: 60 # Optional time between taking humidity samples in seconds, default 300 seconds min_humidity: 55 # Optional minimum humidity to enable dehumidification. Default = 0 unique_id: master_bathroom_hygrostat # Optional ID that uniquely identifies this sensor. Set this to a unique value to allow customization through the UI. - platform: generic_hygrostat name: Utility Room Hygrostat sensor: sensor.utility_room_multisensor_relative_humidity # Source humidity sensor #attribute: humidity # Optional use sensor attribute instead of state. delta_trigger: 5 # Optional humidity swing to detect. Default = 3 target_offset: 10 # Optional dehumidification target offset. Default = 3 min_on_time: 300 # Optional min on time in seconds. Default = 0 seconds max_on_time: 1800 # Optional safety max on time in seconds. Default = 7200 seconds sample_interval: 60 # Optional time between taking humidity samples in seconds, default 300 seconds min_humidity: 55 # Optional minimum humidity to enable dehumidification. Default = 0 unique_id: utility_room_hygrostat # Optional ID that uniquely identifies this sensor. Set this to a unique value to allow customization through the UI.