Will pushing from the server break anything?
This commit is contained in:
+105
-105
@@ -1,106 +1,106 @@
|
||||
bme680_bsec:
|
||||
# id
|
||||
# -----------
|
||||
# Identifier for this component, useful when working with multiple devices.
|
||||
# Must be unique, and can be used in the sensor sections to refer to the correct device.
|
||||
# Default: auto-computed
|
||||
id: bme680_internal
|
||||
|
||||
# i2c address
|
||||
# -----------
|
||||
# Common values are:
|
||||
# - 0x76
|
||||
# - 0x77
|
||||
# Default: 0x76
|
||||
address: 0x76
|
||||
|
||||
# Temperature offset
|
||||
# ------------------
|
||||
# Useful if device is in enclosure and reads too high
|
||||
# For example, if it reads 5C too high, set this to 5
|
||||
# This also corrects the relative humidity readings
|
||||
# Default: 0
|
||||
temperature_offset: 0
|
||||
|
||||
# IAQ calculation mode
|
||||
# --------------------
|
||||
# Available options:
|
||||
# - static (for fixed position devices)
|
||||
# - mobile (for on a person or other moveable devices)
|
||||
# Default: static
|
||||
iaq_mode: static
|
||||
|
||||
# Supply voltage
|
||||
# --------------------
|
||||
# Available options:
|
||||
# - 3.3V
|
||||
# - 1.8V
|
||||
# Default: 3.3V
|
||||
supply_voltage: 3.3V
|
||||
|
||||
# Sample rate
|
||||
# -----------
|
||||
# Available options:
|
||||
# - lp (low power - samples every 3 seconds)
|
||||
# - ulp (ultra-low power - samples every 5 minutes)
|
||||
# Default: lp
|
||||
sample_rate: ulp
|
||||
|
||||
# Interval at which to save BSEC state
|
||||
# ------------------------------------
|
||||
# Default: 6h
|
||||
state_save_interval: 6h
|
||||
|
||||
sensor:
|
||||
- platform: bme680_bsec
|
||||
# ID of the bme680_bsec component to use for the next sensors.
|
||||
# Useful when working with multiple devices
|
||||
bme680_bsec_id: bme680_internal
|
||||
|
||||
temperature:
|
||||
# Temperature in °C
|
||||
name: "BME680 Temperature"
|
||||
sample_rate: lp
|
||||
filters:
|
||||
- median
|
||||
pressure:
|
||||
# Pressure in hPa
|
||||
name: "BME680 Pressure"
|
||||
sample_rate: lp
|
||||
filters:
|
||||
- median
|
||||
humidity:
|
||||
# Relative humidity %
|
||||
name: "BME680 Humidity"
|
||||
sample_rate: lp
|
||||
filters:
|
||||
- median
|
||||
gas_resistance:
|
||||
# Gas resistance in Ω
|
||||
name: "BME680 Gas Resistance"
|
||||
filters:
|
||||
- median
|
||||
iaq:
|
||||
# Indoor air quality value
|
||||
name: "BME680 IAQ"
|
||||
filters:
|
||||
- median
|
||||
iaq_accuracy:
|
||||
# IAQ accuracy as a numeric value of 0, 1, 2, 3
|
||||
name: "BME680 Numeric IAQ Accuracy"
|
||||
co2_equivalent:
|
||||
# CO2 equivalent estimate in ppm
|
||||
name: "BME680 CO2 Equivalent"
|
||||
filters:
|
||||
- median
|
||||
breath_voc_equivalent:
|
||||
# Volatile organic compounds equivalent estimate in ppm
|
||||
name: "BME680 Breath VOC Equivalent"
|
||||
filters:
|
||||
- median
|
||||
|
||||
text_sensor:
|
||||
- platform: bme680_bsec
|
||||
iaq_accuracy:
|
||||
# IAQ accuracy as a text value of Stabilizing, Uncertain, Calibrating, Calibrated
|
||||
bme680_bsec:
|
||||
# id
|
||||
# -----------
|
||||
# Identifier for this component, useful when working with multiple devices.
|
||||
# Must be unique, and can be used in the sensor sections to refer to the correct device.
|
||||
# Default: auto-computed
|
||||
id: bme680_internal
|
||||
|
||||
# i2c address
|
||||
# -----------
|
||||
# Common values are:
|
||||
# - 0x76
|
||||
# - 0x77
|
||||
# Default: 0x76
|
||||
address: 0x76
|
||||
|
||||
# Temperature offset
|
||||
# ------------------
|
||||
# Useful if device is in enclosure and reads too high
|
||||
# For example, if it reads 5C too high, set this to 5
|
||||
# This also corrects the relative humidity readings
|
||||
# Default: 0
|
||||
temperature_offset: 0
|
||||
|
||||
# IAQ calculation mode
|
||||
# --------------------
|
||||
# Available options:
|
||||
# - static (for fixed position devices)
|
||||
# - mobile (for on a person or other moveable devices)
|
||||
# Default: static
|
||||
iaq_mode: static
|
||||
|
||||
# Supply voltage
|
||||
# --------------------
|
||||
# Available options:
|
||||
# - 3.3V
|
||||
# - 1.8V
|
||||
# Default: 3.3V
|
||||
supply_voltage: 3.3V
|
||||
|
||||
# Sample rate
|
||||
# -----------
|
||||
# Available options:
|
||||
# - lp (low power - samples every 3 seconds)
|
||||
# - ulp (ultra-low power - samples every 5 minutes)
|
||||
# Default: lp
|
||||
sample_rate: ulp
|
||||
|
||||
# Interval at which to save BSEC state
|
||||
# ------------------------------------
|
||||
# Default: 6h
|
||||
state_save_interval: 6h
|
||||
|
||||
sensor:
|
||||
- platform: bme680_bsec
|
||||
# ID of the bme680_bsec component to use for the next sensors.
|
||||
# Useful when working with multiple devices
|
||||
bme680_bsec_id: bme680_internal
|
||||
|
||||
temperature:
|
||||
# Temperature in °C
|
||||
name: "BME680 Temperature"
|
||||
sample_rate: lp
|
||||
filters:
|
||||
- median
|
||||
pressure:
|
||||
# Pressure in hPa
|
||||
name: "BME680 Pressure"
|
||||
sample_rate: lp
|
||||
filters:
|
||||
- median
|
||||
humidity:
|
||||
# Relative humidity %
|
||||
name: "BME680 Humidity"
|
||||
sample_rate: lp
|
||||
filters:
|
||||
- median
|
||||
gas_resistance:
|
||||
# Gas resistance in Ω
|
||||
name: "BME680 Gas Resistance"
|
||||
filters:
|
||||
- median
|
||||
iaq:
|
||||
# Indoor air quality value
|
||||
name: "BME680 IAQ"
|
||||
filters:
|
||||
- median
|
||||
iaq_accuracy:
|
||||
# IAQ accuracy as a numeric value of 0, 1, 2, 3
|
||||
name: "BME680 Numeric IAQ Accuracy"
|
||||
co2_equivalent:
|
||||
# CO2 equivalent estimate in ppm
|
||||
name: "BME680 CO2 Equivalent"
|
||||
filters:
|
||||
- median
|
||||
breath_voc_equivalent:
|
||||
# Volatile organic compounds equivalent estimate in ppm
|
||||
name: "BME680 Breath VOC Equivalent"
|
||||
filters:
|
||||
- median
|
||||
|
||||
text_sensor:
|
||||
- platform: bme680_bsec
|
||||
iaq_accuracy:
|
||||
# IAQ accuracy as a text value of Stabilizing, Uncertain, Calibrating, Calibrated
|
||||
name: "BME680 IAQ Accuracy"
|
||||