updating common esphome sensors

finally fixing hvac-multisensor. All of this was caused by the display switch referenced the display while it wasn't plugged in. Updated code to check for the existence first.
This commit is contained in:
CeeWeasel
2025-07-20 12:33:08 -04:00
parent 4e0e55ac3c
commit 75fb9c2ab8
31 changed files with 1315 additions and 600 deletions
+59 -61
View File
@@ -1,25 +1,49 @@
# 3v3 en svp sun 34 35 32 33 25 26 27 14 12 gnd 13 sd2 sd3 gnd 5v
substitutions:
devicename: furnace-room-multisensor
entity_name: furnace_room_multisensor
friendly_name: Furnace Room MultiSensor
comment: Clever MultiSensor
platform: ESP32
board: nodemcu-32s
board: wemos_d1_mini32
static_ip: !secret furnace-room-multisensor-ip
sda_pin: GPIO21
scl_pin: GPIO22
door_pin: GPIO19
one_wire_pin: GPIO14
trigger_pin: GPIO04
echo_pin: GPIO12
#mdc_pin: GPIO23
#mdio_pin: GPIO18
#clk_mode: GPIO17_OUT
#power_pin: GPIO5
packages:
#wifi: !include common/wifi.yaml
ethernet: !include common/olimex-evb.yaml
#wifi: !include common/wifi_no_power_save.yaml
ethernet: !include common/ethernet.yaml
device_base: !include common/device_base.yaml
ble_proxy: !include common/ble_proxy.yaml
esp32:
board: esp32-poe-iso
esphome:
name: ${devicename}
friendly_name: ${friendly_name}
esp32:
board: ${board}
framework:
type: esp-idf
# Enable logging
logger:
level: DEBUG
logs:
dallas.sensor: NONE
sensor: NONE
api: # Using settings from common/device_base.yaml
ota: # Using settings from common/device_base.yaml
esp32_ble_tracker:
globals:
- id: screen_power
@@ -32,14 +56,13 @@ font:
id: font1
size: 17
dallas_temp:
- pin:
number: GPIO5 #D4
update_interval: 10s
one_wire:
- platform: gpio
pin: ${one_wire_pin}
i2c:
sda: GPIO13 #D1
scl: GPIO15 #D2
sda: ${sda_pin}
scl: ${scl_pin}
frequency: 800kHz
display:
@@ -49,48 +72,51 @@ display:
#reset_pin: GPIO14 #D0
address: 0x3C
lambda: |-
it.print(0, 0, id(font1), "Delt:");
it.print(0, 0, id(font1), "Delta:");
it.printf(128, 0, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_delta).state);
it.print(0, 16, id(font1), "HVAC:");
it.printf(128, 16, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac).state);
it.print(0, 32, id(font1), "Retn:");
it.print(0, 16, id(font1), "Supply:");
it.printf(128, 16, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_supply).state);
it.print(0, 32, id(font1), "Return:");
it.printf(128, 32, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(hvac_return).state);
it.print(0, 48, id(font1), "Ambt:");
it.print(0, 48, id(font1), "Ambient:");
it.printf(128, 48, id(font1), TextAlign::TOP_RIGHT, "%.1f°F", id(ambient).state);
sensor:
- platform: dallas
- platform: dallas_temp
address: 0xB33C01B607798528
name: "Return Temperature"
id: hvac_return
update_interval: 10s
filters:
- lambda: return x * (9.0/5.0) + 32.0;
unit_of_measurement: "°F"
state_class: measurement
- platform: dallas
- platform: dallas_temp
address: 0x0F3C01B6070C1328
name: "HVAC Temperature"
id: hvac
name: "Supply Temperature"
id: hvac_supply
update_interval: 10s
filters:
- lambda: return x * (9.0/5.0) + 32.0;
unit_of_measurement: "°F"
state_class: measurement
- platform: dallas
- platform: dallas_temp
address: 0xFA3C01B607005B28
name: "Furnace Room Temperature"
name: "Ambient Temperature"
id: ambient
update_interval: 10s
filters:
- lambda: return x * (9.0/5.0) + 32.0;
unit_of_measurement: "°F"
state_class: measurement
- platform: template
name: "HVAC Delta"
name: "Delta Temperature"
id: hvac_delta
lambda: |-
return (id(hvac).state - id(hvac_return).state);
return (id(hvac_supply).state - id(hvac_return).state);
update_interval: 10s
unit_of_measurement: "°F"
state_class: measurement
@@ -99,37 +125,9 @@ sensor:
- throttle: 60s
- delta: 1.0
# - platform: ultrasonic
# trigger_pin: GPIO1 #D7
# echo_pin: GPIO5 #D8
# name: "Salt Level in percent"
# update_interval: 1s
# #update_interval: 10s
# filters:
# - lambda: return (0.86-x)*(100/0.86);
# unit_of_measurement: "%"
# - platform: ultrasonic
# trigger_pin: GPIO33 #D7
# echo_pin: GPIO35 #D8
# unit_of_measurement: "cm"
# id: distance_from_bottom
# name: "Salt Level in CM"
# # pulse_time: 10us
# #update_interval: 3h
# #update_interval: 5s
# #timeout: 4.0m
# update_interval: 5s
# filters:
# - lambda: return ( 0.86 - x * 100;
# - sliding_window_moving_average:
# window_size: 5
# send_every: 5
# send_first_at: 1
- platform: ultrasonic
trigger_pin: GPIO33 #D7
echo_pin: GPIO35 #D8
trigger_pin: ${trigger_pin}
echo_pin: ${echo_pin}
id: ultrasonic_source
#update_interval: 5s
internal: True
@@ -182,10 +180,10 @@ sensor:
binary_sensor:
- platform: gpio
name: "Furnace Room Door"
name: "Door"
device_class: door
pin:
number: GPIO3 #D5
number: ${door_pin}
mode: INPUT_PULLUP
- platform: homeassistant
@@ -206,7 +204,7 @@ binary_sensor:
switch:
- platform: template
id: display_switch
name: "HVAC Display Switch"
name: "Display"
lambda: |-
if (id(screen_power)) {
id(oled).turn_on();