# CT01 - A - Grid Phase A
# CT02 - G - Dryer
# CT03 - D - Furnace
# CT04 - B - Grid Phase B
# CT05 - E - Basement Plugs (Computer is on this circuit)
# CT06 - F - Nursery, Kitchen, and Dining Room Lights
# CT07 - C - Sump Pump Plug
# CT08 - H - Microwave Plug
# CT09 - I - Stove/Oven
# CT10 - J - Front Room Plugs
# CT11 - M - Heat Pump
# CT12 - L - Kitchen Circuit 1 (Fridge is on this circuit)
substitutions:
devicename: power-monitor
disp_name: power-monitor
friendly_name: 'PM:'
entity_name: power_monitor
comment: Clever Power Monitor
static_ip: !secret power-monitor-ip
platform: ESP32
board: nodemcu-32s
update_time: 500ms
kwh_report_interval: 60s
watt_heartbeat: 60s
throttle_time: 60s
watt_delta: "50.0"
#watt_delta: "5.0"
#grid_watt_delta: "10.0"
grid_watt_delta: "200.0"
#fast_update_time: 10s
#medium_update_time: 30s
#slow_update_time: 60s
main_meter_name1: Meter 1-3
main_meter_name2: Meter 4-6
main_meter_id1: meter_main1
main_meter_id2: meter_main2
## Addon1
addon1_name1: Addon1 7-9
addon1_name2: Addon1 10-12
addon1_id1: addon1_1
addon1_id2: addon1_2
## Addon2
addon2_name1: Addon2 13-15
addon2_name2: Addon2 16-18
addon2_id1: addon2_1
addon2_id2: addon2_2
## Addon3
addon3_name1: Addon3 19-21
addon3_name2: Addon3 22-24
addon3_id1: addon3_1
addon3_id2: addon3_2
ct1_name: 'Grid Phase A'
ct4_name: 'Grid Phase B'
ct22_name: 'Well' # 1, 3 # sct010 - O
ct12_name: 'Kitchen 1' # 5 # sct006 - L
ct16_name: 'Kitchen 2' # 7 # sct006 - S
ct18_name: 'Laundry Plug' # 9 # sct006 - N
ct8_name: 'Microwave Plug' # 11 # sct006 - H
ct17_name: 'Bathroom Plug' # 13 # sct006 - R
ct11_name: 'Heat Pump' # 15, 17 - M
ct24_name: 'Basement Bedroom and Furnace Room Lights' # 19 # sct006 - K
ct5_name: 'Basement Plugs' # 21a # sct006 - E
ct23_name: 'Basement and Laundry Lights and Plugs' # 21b # sct006 - W
ct7_name: 'Sump Pump Plug' # 23 # sct006 - C
ct6_name: 'Nursery, Dining, Kitchen Lights' # 2 # sct006 - F
ct20_name: 'Master Suite' # 4 # sct006 - T
ct3_name: 'Furnace' # 6 # sct006 - D
ct15_name: 'Basement Stairs and Lights' # 8 # sct006 - P
ct21_name: 'Dishwasher' # 10 # sct006 - V
ct13_name: 'Garage Outside and Front Garage Lights' # 12 # sct006 - U
ct10_name: 'Front Room Plugs' # 14 # sct006 - J
ct14_name: 'Garage and Outside Plugs' # 16 # sct006 - Q
ct9_name: 'Stove' # 18, 20 # sct016 - I
ct2_name: 'Dryer' # 22, 24 # sct010 - G
ct19_name: 'Unused'
# Current Transformers:
# 20A/25mA SCT-006: 11143
sct006: '11143'
# 30A/1V SCT-013-030: 8650
# 50A/1V SCT-013-050: 15420
# 80A/26.6mA SCT-010: 41660
sct010: '41660'
# 100A/50ma SCT-013-000: 27518
sct013: '27518'
# 120A/40mA: SCT-016: 41787
sct016: '41787'
# 200A/100mA SCT-024: 27518
#current_cal: '27518'
# Jameco 9VAC Transformer:
# For meter versions:
# >= v1.3: 7305
#voltage_cal: '7305'
## Main Board
current_cal_ct1: '41787'
current_cal_ct2: '41660'
current_cal_ct3: '11143'
current_cal_ct4: '41787'
current_cal_ct5: '11143'
current_cal_ct6: '11143'
## Addon1
current_cal_ct7: '11143'
current_cal_ct8: '11143'
current_cal_ct9: '27518'
current_cal_ct10: '11143'
current_cal_ct11: '41660'
current_cal_ct12: '11143'
## Addon2
current_cal_ct13: '11143'
current_cal_ct14: '11143'
current_cal_ct15: '11143'
current_cal_ct16: '11143'
current_cal_ct17: '11143'
current_cal_ct18: '11143'
## Addon3
current_cal_ct19: '11143'
current_cal_ct20: '11143'
current_cal_ct21: '11143'
current_cal_ct22: '41660'
current_cal_ct23: '11143'
current_cal_ct24: '11143'
# This only needs to be changed if you're using something other than the
# Jameco 9VAC Transformer:
voltage_cal1: '7305'
voltage_cal2: '7305'
electric_freq: "60Hz"
offset_calibration: "true"
gain_calibration: "true"
# spi_clk: 18
# spi_miso: 19
# spi_mosi: 23
# ic1_main: 5
# ic1_addon1: 0
# ic1_addon2: 27
# ic1_addon3: 2
# ic2_main: 4
# ic2_addon1: 16
# ic2_addon2: 17
# ic2_addon3: 21
# ethernet:
# id: eth
# type: W5500
# clk_pin: GPIO13
# mosi_pin: GPIO11
# miso_pin: GPIO12
# cs_pin: GPIO14
# interrupt_pin: GPIO10
# reset_pin: GPIO9
esphome:
name: ${disp_name}
friendly_name: "${friendly_name}"
name_add_mac_suffix: true
min_version: '2025.7.0'
project:
name: circuitsetup.6c-energy-meter-3-addons
version: "1.7"
packages:
wifi: !include common/wifi.yaml
# device_base: !include common/complex_esp32_base.yaml
common: !include circuit-setup/6chan_common.yaml
main: !include circuit-setup/meter_sensors/6chan_main_sensor.yaml
main_status: !include circuit-setup/status_fields/6chan_main_status.yaml
main_cal: !include circuit-setup/calibration/6chan_main_calibration.yaml
addon_1: !include circuit-setup/meter_sensors/6chan_addon1.yaml
addon_2: !include circuit-setup/meter_sensors/6chan_addon2.yaml
addon_3: !include circuit-setup/meter_sensors/6chan_addon3.yaml
# Enable Home Assistant API
# An encryption key is recommended and can be generated here:
# https://esphome.io/components/api.html#configuration-variables
api:
# encryption:
# key: "YOUR_ENCRYPTION_KEY_HERE"
# Enable OTA updating
ota:
- platform: esphome
# In combination with the `ap` this allows
# provisioning wifi credentials to the device.
captive_portal:
# Sets up Bluetooth LE to provision wifi credentials
# to the device.
esp32_improv:
authorizer: none
# Sets up the improv via serial client for wifi provisioning
improv_serial:
web_server:
port: 80
sensor:
## The max value for current that the meter can output is 65.535. If you expect to measure current over 65A,
## divide the current_cal_ctx (above) by 2 (120A CT) or 4 (200A CT) and multiply the current and power values
## by 2 or 4, uncommenting the below and changing the id and phase_x accordingly
#- id: !extend ${main_meter_id1} # CTs 1-3
# phase_a: # CT1
# current:
# filters:
# - multiply: 2
# power:
# filters:
# - multiply: 2
#
## uncomment if monitoring 2 voltages
#- id: !extend ${main_meter_id2}
# phase_a:
# voltage:
# name: Voltage 2
# id: ic2Volts
# accuracy_decimals: 1
# frequency:
# name: Frequency 2
## Comment out to show amps and watts per meter board in Home Assistant
- id: !extend totalAmpsMain
internal: true
- id: !extend totalWattsMain
internal: true
- id: !extend totalAmpsAddOn1
internal: true
- id: !extend totalWattsAddOn1
internal: true
- id: !extend totalAmpsAddOn2
internal: true
- id: !extend totalWattsAddOn2
internal: true
- id: !extend totalAmpsAddOn3
internal: true
- id: !extend totalWattsAddOn3
internal: true
#Total Amps
###########
- platform: template
name: ${friendly_name} Total Amps
id: totalAmps
lambda: return id(totalAmpsMain).state + id(totalAmpsAddOn1).state + id(totalAmpsAddOn2).state + id(totalAmpsAddOn3).state ;
accuracy_decimals: 2
unit_of_measurement: A
device_class: current
update_interval: ${update_time}
#Total Watts
############
- platform: template
name: ${friendly_name} Total Watts
id: totalWatts
lambda: return id(totalWattsMain).state + id(totalWattsAddOn1).state + id(totalWattsAddOn2).state + id(totalWattsAddOn3).state ;
accuracy_decimals: 1
unit_of_measurement: W
device_class: power
update_interval: ${update_time}
#kWh
####
- platform: total_daily_energy
name: ${friendly_name} Total kWh
power_id: totalWatts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
+847
View File
@@ -0,0 +1,847 @@
# CT01 - A - Grid Phase A
# CT02 - G - Dryer
# CT03 - D - Furnace
# CT04 - B - Grid Phase B
# CT05 - E - Basement Plugs (Computer is on this circuit)
# CT06 - F - Nursery, Kitchen, and Dining Room Lights
# CT07 - C - Sump Pump Plug
# CT08 - H - Microwave Plug
# CT09 - I - Stove/Oven
# CT10 - J - Front Room Plugs
# CT11 - M - Heat Pump
# CT12 - L - Kitchen Circuit 1 (Fridge is on this circuit)
substitutions:
devicename: power-monitor
friendly_name: 'PM:'
entity_name: power_monitor
comment: Clever Power Monitor
static_ip: !secret power-monitor-ip
platform: ESP32
board: nodemcu-32s
update_time: 500ms
kwh_report_interval: 60s
watt_heartbeat: 60s
throttle_time: 60s
watt_delta: "50.0"
#watt_delta: "5.0"
#grid_watt_delta: "10.0"
grid_watt_delta: "200.0"
#fast_update_time: 10s
#medium_update_time: 30s
#slow_update_time: 60s
ct01Name: 'Grid Phase A'
ct04Name: 'Grid Phase B'
ct22Name: 'Well' # 1, 3 # sct010 - O
ct12Name: 'Kitchen 1' # 5 # sct006 - L
ct16Name: 'Kitchen 2' # 7 # sct006 - S
ct18Name: 'Laundry Plug' # 9 # sct006 - N
ct08Name: 'Microwave Plug' # 11 # sct006 - H
ct17Name: 'Bathroom Plug' # 13 # sct006 - R
ct11Name: 'Heat Pump' # 15, 17 - M
ct24Name: 'Basement Bedroom and Furnace Room Lights' # 19 # sct006 - K
ct05Name: 'Basement Plugs' # 21a # sct006 - E
ct23Name: 'Basement and Laundry Lights and Plugs' # 21b # sct006 - W
ct07Name: 'Sump Pump Plug' # 23 # sct006 - C
ct06Name: 'Nursery, Dining, Kitchen Lights' # 2 # sct006 - F
ct20Name: 'Master Suite' # 4 # sct006 - T
ct03Name: 'Furnace' # 6 # sct006 - D
ct15Name: 'Basement Stairs and Lights' # 8 # sct006 - P
ct21Name: 'Dishwasher' # 10 # sct006 - V
ct13Name: 'Garage Outside and Front Garage Lights' # 12 # sct006 - U
ct10Name: 'Front Room Plugs' # 14 # sct006 - J
ct14Name: 'Garage and Outside Plugs' # 16 # sct006 - Q
ct09Name: 'Stove' # 18, 20 # sct016 - I
ct02Name: 'Dryer' # 22, 24 # sct010 - G
ct19Name: 'Unused'
# Current Transformers:
# 20A/25mA SCT-006: 11143
sct006: '11143'
# 30A/1V SCT-013-030: 8650
# 50A/1V SCT-013-050: 15420
# 80A/26.6mA SCT-010: 41660
sct010: '41660'
# 100A/50ma SCT-013-000: 27518
sct013: '27518'
# 120A/40mA: SCT-016: 41787
sct016: '41787'
# 200A/100mA SCT-024: 27518
#current_cal: '27518'
# Jameco 9VAC Transformer:
# For meter versions:
# >= v1.3: 7305
voltage_cal: '7305'
spi_clk: 18
spi_miso: 19
spi_mosi: 23
ic1_main: 5
ic1_addon1: 0
ic1_addon2: 27
ic1_addon3: 2
ic2_main: 4
ic2_addon1: 16
ic2_addon2: 17
ic2_addon3: 21
# ethernet:
# id: eth
# type: W5500
# clk_pin: GPIO13
# mosi_pin: GPIO11
# miso_pin: GPIO12
# cs_pin: GPIO14
# interrupt_pin: GPIO10
# reset_pin: GPIO9
packages:
wifi: !include common/wifi.yaml
# device_base: !include common/complex_esp32_base.yaml
device_base: !include common/device_base.yaml
mqtt: !include common/mqtt_null.yaml
esp32:
board: nodemcu-32s
# web_server:
# port: 80
time:
- platform: sntp
id: sntp_time
timezone: America/Detroit
logger:
# level: DEBUG
# logs:
# sensor: DEBUG
spi:
clk_pin: ${spi_clk}
miso_pin: ${spi_miso}
mosi_pin: ${spi_mosi}
sensor:
#IC1 Main
- platform: atm90e32
cs_pin: ${ic1_main}
phase_a:
voltage:
name: ${friendly_name} [V]
id: ic1Volts
filters:
- throttle_average: 60s
accuracy_decimals: 1
current:
name: ${friendly_name} ${ct01Name} [A]
id: ct1Amps
filters:
- or:
- delta: 2
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
power:
name: ${friendly_name} ${ct01Name} [W]
id: ct1Watts
filters:
- or:
- delta: ${grid_watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct016}
phase_b:
power:
name: ${friendly_name} ${ct02Name} [W]
id: ct2Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct010}
phase_c:
power:
name: ${friendly_name} ${ct03Name} [W]
id: ct3Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
frequency:
name: ${friendly_name} Freq A
filters:
- or:
- delta: 0.05
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC2 Main
- platform: atm90e32
cs_pin: ${ic2_main}
phase_a:
current:
name: ${friendly_name} ${ct04Name} [A]
id: ct4Amps
filters:
- or:
- delta: ${grid_watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
power:
name: ${friendly_name} ${ct04Name} [W]
id: ct4Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
gain_voltage: ${voltage_cal}
gain_ct: ${sct016}
phase_b:
power:
name: ${friendly_name} ${ct05Name} [W]
id: ct5Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_c:
power:
name: ${friendly_name} ${ct06Name} [W]
id: ct6Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
frequency:
name: ${friendly_name} Freq B
filters:
- or:
- delta: 0.05
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC1 AddOn 1
- platform: atm90e32
cs_pin: ${ic1_addon1}
phase_a:
power:
name: ${friendly_name} ${ct07Name} [W]
id: ct7Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_b:
power:
name: ${friendly_name} ${ct08Name} [W]
id: ct8Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_c:
power:
name: ${friendly_name} ${ct09Name} [W]
id: ct9Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct013}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC2 AddOn 1
- platform: atm90e32
cs_pin: ${ic2_addon1}
phase_a:
power:
name: ${friendly_name} ${ct10Name} [W]
id: ct10Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_b:
power:
name: ${friendly_name} ${ct11Name} [W]
id: ct11Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct010}
phase_c:
power:
name: ${friendly_name} ${ct12Name} [W]
id: ct12Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC1 AddOn 2
- platform: atm90e32
cs_pin: ${ic1_addon2}
phase_a:
power:
name: ${friendly_name} ${ct13Name} [W]
id: ct13Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_b:
power:
name: ${friendly_name} ${ct14Name} [W]
id: ct14Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_c:
power:
name: ${friendly_name} ${ct15Name} [W]
id: ct15Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC2 AddOn 2
- platform: atm90e32
cs_pin: ${ic2_addon2}
phase_a:
power:
name: ${friendly_name} ${ct16Name} [W]
id: ct16Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_b:
power:
name: ${friendly_name} ${ct17Name} [W]
id: ct17Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_c:
power:
name: ${friendly_name} ${ct18Name} [W]
id: ct18Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC1 AddOn 3
- platform: atm90e32
#do not use GPIO2 if ESP32 has an on-board LED assigned to it
cs_pin: ${ic1_addon3}
phase_a:
power:
name: ${friendly_name} ${ct19Name} [W]
id: ct19Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_b:
power:
name: ${friendly_name} ${ct20Name} [W]
id: ct20Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_c:
power:
name: ${friendly_name} ${ct21Name} [W]
id: ct21Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
qos: 1
retain: true
availability:
topic: ${mqtt_root_topic}/${devicename}/${ct21Name}_w/status
payload_available: online
payload_not_available: offline
state_topic: ${mqtt_root_topic}/${devicename}/${ct21Name}_w
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#IC2 AddOn 3
- platform: atm90e32
cs_pin: ${ic2_addon3}
phase_a:
power:
#name: ${friendly_name} ${ct22Name} [W]
internal: true
id: ct22Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct010}
phase_b:
power:
name: ${friendly_name} ${ct23Name} [W]
id: ct23Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
phase_c:
power:
name: ${friendly_name} ${ct24Name} [W]
id: ct24Watts
filters:
- or:
- delta: ${watt_delta}
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
- multiply: -1
accuracy_decimals: 1
gain_voltage: ${voltage_cal}
gain_ct: ${sct006}
line_frequency: 60Hz
gain_pga: 1X
update_interval: ${update_time}
#Total Amps From Grid
- platform: template
name: ${friendly_name} Grid Total [A]
id: totalAmpsFromGrid
lambda: return id(ct1Amps).state + id(ct4Amps).state ;
accuracy_decimals: 1
unit_of_measurement: A
device_class: current
state_class: measurement
update_interval: ${update_time}
filters:
- or:
- delta: 2.0
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
#Total Watts From Grid
- platform: template
name: ${friendly_name} Grid Total [W]
id: totalWattsFromGrid
lambda: return id(ct1Watts).state + id(ct4Watts).state ;
accuracy_decimals: 1
unit_of_measurement: W
device_class: power
state_class: measurement
update_interval: ${update_time}
filters:
- or:
- delta: 5.0
- throttle_average: ${throttle_time}
# - heartbeat: ${watt_heartbeat}
#kWh From Grid
- platform: total_daily_energy
name: ${friendly_name} Grid [kWh]
power_id: totalWattsFromGrid
filters:
- multiply: 0.001
# - heartbeat: ${kwh_report_interval}
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
# The CT for the Well needs to be calibrated.
# In the interim, I'm using this lambda
- platform: template
name: ${friendly_name} ${ct22Name} [W]
id: ct22WattsPositive
state_class: measurement
lambda: |-
if (id(ct22Watts).state < 0){
return 0;
} else {
return id(ct22Watts).state ;
}
accuracy_decimals: 1
unit_of_measurement: W
icon: mdi:lightning-bolt-circle
update_interval: ${update_time}
filters:
- delta: 5.0
# - heartbeat: ${watt_heartbeat}
# kWh from CT1
# This is included in the grid calculation
# kWh from CT2 (the dryer)
- platform: total_daily_energy
name: ${friendly_name} ${ct02Name} [kWh]
power_id: ct2Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 3
- platform: total_daily_energy
name: ${friendly_name} ${ct03Name} [kWh]
power_id: ct3Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
# kWh From CT 4
# This is included in the Grid calculation area
#kWh From CT 5
- platform: total_daily_energy
name: ${friendly_name} ${ct05Name} [kWh]
power_id: ct5Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 6
- platform: total_daily_energy
name: ${friendly_name} ${ct06Name} [kWh]
power_id: ct6Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 7
- platform: total_daily_energy
name: ${friendly_name} ${ct07Name} [kWh]
power_id: ct7Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 8
- platform: total_daily_energy
name: ${friendly_name} ${ct08Name} [kWh]
power_id: ct8Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 9
- platform: total_daily_energy
name: ${friendly_name} ${ct09Name} [kWh]
power_id: ct9Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 10
- platform: total_daily_energy
name: ${friendly_name} ${ct10Name} [kWh]
power_id: ct10Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 11 (Heat Pump)
- platform: total_daily_energy
name: ${friendly_name} ${ct11Name} [kWh]
power_id: ct11Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 12
- platform: total_daily_energy
name: ${friendly_name} ${ct12Name} [kWh]
power_id: ct12Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 13
- platform: total_daily_energy
name: ${friendly_name} ${ct13Name} [kWh]
power_id: ct13Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 14
- platform: total_daily_energy
name: ${friendly_name} ${ct14Name} [kWh]
power_id: ct14Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 15
- platform: total_daily_energy
name: ${friendly_name} ${ct15Name} [kWh]
power_id: ct15Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 16
- platform: total_daily_energy
name: ${friendly_name} ${ct16Name} [kWh]
power_id: ct16Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 17
- platform: total_daily_energy
name: ${friendly_name} ${ct17Name} [kWh]
power_id: ct17Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 18
- platform: total_daily_energy
name: ${friendly_name} ${ct18Name} [kWh]
power_id: ct18Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 19
# this is not used
# - platform: total_daily_energy
# name: ${friendly_name} ${ct19Name} [kWh]
# power_id: ct19Watts
# filters:
# - multiply: 0.001
# - throttle_average: ${kwh_report_interval}
# unit_of_measurement: kWh
# device_class: energy
# state_class: total_increasing
# # min_save_interval: ${update_time}
#kWh From CT 20
- platform: total_daily_energy
name: ${friendly_name} ${ct20Name} [kWh]
power_id: ct20Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 21
- platform: total_daily_energy
name: ${friendly_name} ${ct21Name} [kWh]
power_id: ct21Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
qos: 1
retain: true
availability:
topic: ${mqtt_root_topic}/${devicename}/${ct21Name}_kwh/status
payload_available: online
payload_not_available: offline
state_topic: ${mqtt_root_topic}/${devicename}/${ct21Name}_kwh
# min_save_interval: ${update_time}
#kWh From CT 22
- platform: total_daily_energy
name: ${friendly_name} ${ct22Name} [kWh]
power_id: ct22WattsPositive
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 23
- platform: total_daily_energy
name: ${friendly_name} ${ct23Name} [kWh]
power_id: ct23Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}
#kWh From CT 24
- platform: total_daily_energy
name: ${friendly_name} ${ct24Name} [kWh]
power_id: ct24Watts
filters:
- multiply: 0.001
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
# min_save_interval: ${update_time}